This article addresses common FAQs regarding child safety window locks legislation in NSW.
Table of Contents:
- QUESTION: Does the NSW child safety window lock legislation apply if a window opens onto the balcony of a unit?
- ARTICLE: Annual Window Safety Compliance Reinspection – Minimising the Risk of Non-Compliance
- QUESTION: What types of window locking devices are being installed in strata buildings to comply with child safety window locks legislation in NSW?
- QUESTION: Do CrimSafe screens comply with the window locks legislation NSW for apartments.
- QUESTION: I live by myself and don’t ever have small children inside my townhouse. Why has the body corporate contacted me about installing child proof window locks on my windows?
- QUESTION: Two lots in our building have not cooperated with the fitting of child window safety devices. Can our building still get a compliance certificate for the window locks legislation NSW, excluding these lots or are we able to enter and fit without their permission?
- QUESTION: Is the installation of window locks an admin or capital works fund expense?
- QUESTION: Once fitted, why is the maintenance of window locks important for continued compliance with child safety window locks legislation in NSW
Question: Does the NSW child safety window lock legislation apply if a window opens onto the balcony of a unit?
Answer: If the balcony balustrade is compliant with the requirements at the time of construction, then the window restriction won’t come into play.
The requirements are that the window is above 2m from the ground and the windowsill is less than 1.7m from the internal unit floor. If the window is openable great than 125mm then it must be restricted when children are present. If the balcony balustrade is compliant with the requirements at the time of construction, then the window restriction won’t come into play. I hope this answers your query.
Peter Berney
Solutions in Engineering
E: [email protected]
P: 1300 136 036
This post appears in Strata News #629.
NSW: Annual Window Safety Compliance Reinspection – Minimising the Risk of Non-Compliance
Owners Corporations and Strata Managers have a number of responsibilities when it comes to ensuring the safety of others, one of which is Window Safety Compliance.
Designed to reduce the number of injuries and fatalities that occur as a result of children falling out of high-rise windows, certified window safety devices must now be fitted to openable windows sitting 2m or higher above the ground, with an internal height of 1.7m or less. Once engaged, mandatory child window safety locks should only allow windows to open up to 12.5cm.
Introduced in 2013, NSW Window Safety Legislation states that Owners Corporations must have had these approved child safety devices installed on all applicable common property windows from the 13th of March 2018 or be at ‘risk of non-compliance’.
Why are children at risk if windows are non-compliant?
Alarming statistics from the Children’s Hospital at Westmead say that on average, each year, up to 10 children are admitted after falling from a window. These falls often happen in the child’s own home, over the summer months, when windows and balcony doors are left open. With many of these injuries being serious in nature, the likelihood of a child requiring long-term medical care and assistance following a fall is significant.
Why are Owners Corporations at risk if windows are non-compliant?
When it comes to window safety, Strata Owners are often unaware that their building presents a continual risk of personal liability. It is the Owners Corporations responsibility to ensure all openable windows are compliant with NSW Child Window Safety Legislation, as windows are considered common property for maintenance purposes. Penalties now apply for non-compliant Owners Corporations and Lot Owners, who also face fines, depending on the window’s position and the reason for the breach.
The potential for liability, as a result of a window related accident, can be devastating; most importantly from a child safety standpoint, but also from a financial perspective. If reasonable care is not shown to have been taken by the Owners Corporations to satisfy child safety window locks legislative requirements, Strata Insurance coverage could become void. Further to this, third party action could even result in individual Strata Committee members being sued for damages, into the millions.
How do Owners Corporations minimise ongoing risks associated with non-compliance?
Once installed and certified, as per NSW Child Window Safety Device Legislation, the Window Safety obligations of Owners’ Corporations remain ongoing. To ensure compliance all year round, Owners Corporations are advised to complete an Annual Window Safety Compliance Reinspection by qualified, industry professionals.
How Often do Windows Safety Locks Need to be Inspected?
Over time, window safety devices can fail to work, resulting in non-compliant windows. This can be due to device misuse, removal, damage or lost keys. Annual Window Safety Compliance Reinspection can remove any risk of non-compliance for Owners’ Corporations and their Strata Managers, ensuring all Child Window Safety Locks are maintained and certified to be in good working order.
What is an Annual Window Safety Compliance Reinspection?
Annual Window Safety Compliance Reinspection must be performed by certified experts, who test all windows and safety devices in accordance with Section 118 Window safety devices–child safety of the Strata Schemes Management Act 2015. Once checked, they should repair and/or replace non-compliant window safety devices on the spot, where possible, completing the job with an updated certification for each unit.
What are the benefits of an Annual Window Safety Compliance Reinspection?
It’s not always easy for Owners Corporations to monitor the way in which fall prevention devices are being used by the occupants of individual dwellings. By organising annual audits, any child safety window lock problems can be nipped in the bud, eliminating higher maintenance and repair costs down the track. Annual Window Safety Compliance Reinspection will highlight, repair and certify all window safety locks, with minimum disruption to residents. This, in turn, gives peace of mind to Strata Managers and Owners Corporations throughout the year.
With compulsory safety window devices assisting Strata Owners to keep their children safe, Window Safety Compliance Reinspection is helping Owners Corporations minimise the risk of liability associated with window-related accidents on common property. With more children living in NSW apartments than ever before, keeping our children safe is a responsibility for us all.
Anthony Shakar
ASQB
E: [email protected]
T: 02 9785 7893
This post appears in Strata News #219.
Q: What types of window locking devices are being installed in strata buildings to comply with child safety window locks legislation in NSW?
The following responses have been received from members of the strata community. If you have any information to add, please include your thoughts in the comments below.
Clare Dominello, on behalf of Mr Dieb P. Khoury of Benjamin & Khoury Solicitors has supplied an introduction to the topic – window locks legislation NSW.
NSW Fair Trading say: ‘Each year, around 50 children fall from windows or balconies in Australia. Many suffer serious injuries. Sometimes these falls are fatal….’
Have we done enough with the new reforms with our windows and balconies? By 13 March 2018 By-laws had to be compliant. Owners Corporations in NSW are required by law to have window safety devices installed on all above ground windows, both inside windows eg: within your apartment or outside windows eg: Common Areas, gym areas, etc.
Requirements for Window safety and devices for the news window locks legislation NSW
As from March 2018, to help keep our families and friends safe, all Strata Buildings in NSW were required to have fitted, MUST have had fitted as per the new requirements, window devices that allow the window to be locked at 12.5cm when the device is engaged.
The device when activated will not allow the window to open fully. When the device is not activated your window can still open and close fully.
Owners Corporations are responsible for the Common Property they must have safety window devices installed on all common property windows after 13 March 2018. These are windows that are above the ground floor. They must stop the window opening more than 12.5 cm. The safety devices must be child proof and withstand wear and tear.
With the child safety window locks, can I open my window fully?
Yes.
You can still open your windows fully and leave your windows open. As an aid to stop children from falling from windows you have the peace of mind to know that when the window locks are engaged, children are protected from falling out of the window.
Please ensure that your window device is fitted properly. If the window device is loose and not doing the job it should be doing, you and or your strata could be facing non-compliance issues. This is a serious issue and not to be taken lightly. Penalties will be imposed for breaches if the new reforms have not been met.
Do the child safety window locks have to be on the window? Are there any alternatives?
Alternatively, it is possible to consider security screens, bars or grills on the windows. They must not have a gap bigger than 12.5cm. This is the alternative to not having the safety devices installed on the windows.
Remember: Flyscreens are not security screens.
How do I know which window this applies to?
A window within a child’s reach which is less than 1.7 m above the floor and the floor is more than 2 m above the outside ground must have child safety window devices.
Is there a time frame for when the locks must be installed?
The deadline for child safety window locks legislation in NSW was 13 March 2018.
If the window safety requirements have not been met, there is a penalty.
The Owners Corporation in the first instance will face fines, then lot owners will face fines depending on the window’s position and the reason for the breach.
Do CrimSafe screens comply with the window locks legislation NSW for apartments.
Anthony Shakar, ASQB Window Safety provides the following information:
Answer: Fly screens are not security screens and would not pass this pressure test, however to date, we have not had a security grill screen product such as the brand mentioned fail this test.
Window Child Safety Compliance requires that an openable window 2 metres above ground level and then, with a sill located 1.7 metres or less from the internal floor of the unit, be restricted to a maximum opening of 1.25MM whilst children are in the apartment and with a standard outward pressure test of 250 Newton force.
If a window should have a security grill attached then we would apply the same pressure force test on the security grill. It stands to reason (even though it is not the actual window) if it passes the same pressure test as applied to the window restrictive locking devise, a child could not force the security screen open.
Pete Berney, Solutions In Engineering provides the following information:
Solutions in Engineering have been fitting Window Child Safety Devises for over 2 years now. We researched the legislation, purchased and tested many varieties of devices and consulted child services and the Fire department before settling on the keyed lockable devices we currently use.
The issue is not so much the device as is the logistics of organising and gaining access and then obtaining proof that the device was fitted and tested to 250 newtons. We take a photo of every window when it reaches the prescribed newton force. And we came up with providing a certificate of compliance for the building once every open-able window had been tested.
A word of advice to Strata Managers and Executive Committees – do not leave this up to the individual unit owners to do. You will get varying degrees of competency and quality with no record of compliance. It is the Owners Corporations responsibility that all open-able windows be compliant as windows are considered common property for maintenance purposes.
Strata Lawyers have talked about writing By-laws to circumvent this but to no avail as you cannot contract out of a legislative requirement.
Also consider your insurance, what would happen on the advent of a disaster where the owners fitted the lockable devices themselves, ask your insurer what the likely ramifications would be verse having all devices fitted by a reputable firm for the whole building and signed off on as being compliant.
Unfortunately, a child will fall from an “alleged compliant window” in the years to come and the proceeding court case will set a precedent for the cases that follow. An Executive Committee member should greatly consider their exposure to this risk when choosing the method for which to aim to mitigate Window Child Safety Compliance.
You may also be interested in watching this Strata SnapShot series interview featuring Peter Berney, Solutions in Engineering – NSW Strata Window Safety
Lia de Sousa, Whitbread Insurance Brokers has responded regarding the insurance issues raised by Peter Berney above:
We would suggest that the comments from Solutions in Engineering represent an appropriate risk mitigation approach to the matter of complying with NSW Window and Balcony Safety regulations.
The most important factor to consider in relation to the Strata Insurance coverage is that all reasonable care is taken either by the Owners Corporation or Lot Owners, to satisfy the relevant window locks legislation NSW regulations.
Although there are no minimum standards as to the type of locks being installed, we recommend you refer to the following guides provided by the NSW State Government:
This article is not intended to be personal advice and you should not rely on it as a substitute for any form of personal advice. Please contact Whitbread Associates Pty Ltd ABN 69 005 490 228 Licence Number: 229092 trading as Whitbread Insurance Brokers for further information or refer to our website – www.whitbread.com.au or contact us on 1300 424 627.
I live by myself and don’t ever have small children inside my townhouse. Why has the body corporate contacted me about installing child proof window locks on my windows?
Pete Berney, Solutions In Engineering provides the following response to this question:
All strata schemes that contain residential lots where there are openable windows above 2 metres from the ground and then, if less than 1.7m from the internal floor must comply with the window locks legislation NSW. If your Townhouse is part of a Strata Scheme and has openable windows as I’ve described, then the answer is ‘yes, your townhouse must comply’.
If you have good quality security screens such as Amplimesh or Crimsafe already fitted on your windows, they will suffice as we have not had any fail our pressure test (250 newton force). You have mentioned that your windows already have locks and keys fitted. This could mean your Townhouse doesn’t require new devices; however, first you must ensure that the windows are restricted to less than 125mm openings and for best practice, the window won’t open when a force of 250 newtons (equivalent to 25.5kgs) is applied.
The fact that no children live in or even visit your Townhouse is not relevant, as it’s not about the individual owner, it’s about the Owners Corporation’s responsibilities. This is because windows in a strata scheme are considered common property. Once your locks have been confirmed as being compliant, or you’ve had a new device fitted then the good news is that when children are not present, you can have the windows unlocked to allow for ventilation. However, if children are present they must be locked again.
As for allowing a stranger to access your strata home – Under section 122 of the Strata Schemes Management Act 2015 (NSW), ‘An owners corporation for a strata scheme may, by its agents, employees or contractors, enter on any part of the parcel of the scheme for the purpose of carrying out… work required or authorised to be carried out by the owners corporation in accordance with this Act (including work relating to window safety devices and rectification work carried out under Part 11)’. In saying that, your Strata Manager and/or Strata Committee should have sent you information about the contractor including their experience, expertise, insurances, licenses, etc.
In summary – First, check to see if your existing locks will be compliant with window locks legislation NSW. If so, inform your Strata Manager straight away. The manager should then request that the contractor check the locks are compliant. Failure to do so puts the management company at risk in the advent of a fall.
Secondly, ask for the contractor’s details and insurance certificates and inquire about what happens and who pays in the advent of an accident within your Townhouse.
Finally, be happy that you need do nothing more and you’ve helped ensure your Strata Scheme is complaint with the with this piece of legislation, therefore minimising the risk of litigation down the track and helping to protect the lives of children living in or visiting your Strata Scheme.
Jeff Schultz, Express Glass warns there are a lot of cheap devices on the market (although being compliant with child safety window locks legislation for NSW) they are removable and can cause long-term compliance issues. Express Glass have a Handy Guide on Locks Available in the Market. If you are interested in obtaining a copy of the booklet, just email Jeff at [email protected].
Andrew Webster, Australian Child Window Safety sent in the following information about child safety window locks legislation for NSW:
As you are aware, the NSW laws have changed in regards to windows on strata and rented properties. The law states that if you fall into the bracket of their definitions, windows in NSW need to be restricted with window restrictors so a 125mm sphere cannot be passed through the opening at a force of 25Kg, or if correct screens are installed they must withstand the 25Kg force.
There are many products out there to overcome this issue.
We use some of the following products:
Venlock, Remsafe Window Restrictor, Whitco Vent Lock, Whitco Restricted Winders, Kidscreen.
These products can be supplied and installed starting from $45 per window.
For NSW, the window restrictors can be installed by residents, but be warned. They need to be correctly installed and tested.
ACWS can perform a test with a calibrated digital force meter and supply an installation and testing certificate to provide to your insurance company.
A lot of the “fly by nighters” are installing these products and not performing the testing which can leave you a little bit vulnerable with insurance companies in the event of something happening. As the new laws state the window must withhold the 25Kg force.
We are more than happy to provide a free quote to those who still need to comply with the window locks legislation for NSW.
Anthony Montibeler, Director at Norwest Strata Management has contributed this information from a Strata Management point of view:
We can proudly state that 99% of our Owners Corporations are now fully compliant with the new legislation thanks to the efforts of ASQB Window Safety.
Anthony and his team have been fantastic and fully understand the requirements of the window locks legislation NSW. They issue an installation certificate for each lot to state that it complies along with another certificate to state that the Scheme complies once they have installed every lock required.
They have been able to cater for every window they have encountered. Different windows have different requirements so it is best to get the professionals onsite first to check the windows so they can provide the right product for the application.
As Strata Managers we found a benefit to having the Owners Corporation agree to do the whole complex rather than leaving it up to the individual owners to carry out & provide a compliance certificate for their lot only.
Question: Two lots in our building have not cooperated with the fitting of child window safety devices. Can our building still get a compliance certificate for the window locks legislation NSW, excluding these lots or are we able to enter and fit without their permission?
Leanne Habib, Premium Strata answers with the following:
It is arguable whether Section 122 may be used, as the entry required is not really an emergency per se. We feel you would need to obtain orders for access from NCAT instead.
Usually, we would have advised the scheme to implement a by-law regarding the requirement for access, liability, prohibition on malicious damage, tampering etc. prior to having engaged a contract to fulfil the requirements for complying with child safety window locks legislation in NSW.
Is the installation of window locks an admin or capital works fund expense?
Leanne Habib, Premium Strata response with the following information:
The window lock installation would NOT be a recurrent expense but rather a one-off expenditure:
Section 79 Estimates to be prepared of contributions to administrative and capital works funds
- An owners corporation must, not later than 14 days after the constitution of the owners corporation and at each annual general meeting after that, estimate how much money it will need to credit to its administrative fund for actual and expected expenditure:
- to maintain in good condition on a day-to-day basis the common property and any personal property vested in the owners corporation, and
- to provide for insurance premiums, and
- to meet other recurrent expenses.
Recurrent expenses would include such regular expenses as insurance, water charges, electricity charges, carpet cleaning, lawn mowing services and the like and minor expenses relating to maintenance of the common property.
- An owners corporation must, at each annual general meeting, estimate how much money it will need to credit to its capital works fund for actual and expected expenditure:
- for painting or repainting any part of the common property which is a building or other structure, and
- to acquire personal property, and
- to renew or replace personal property, and
- to renew or replace fixtures and fittings that are part of the common property, and
- to replace or repair the common property, and
- to meet other expenses of a capital nature.
Expenses of a capital nature would include expenses in relation to major repairs or improvements to the common property or personal property of the owners corporation, such as replacement of roofing, guttering or fences and the like.
Jeff Gough, Liverpool Glass Company gives you an idea on how much installation costs:
We supply & install window locks for $110 for the first one (per tradesman) as part of the travelling component. $55 for every lock installed whilst onsite after the first on the same day.
E.g. 10 units with 5 windows each = 50 windows x 2 tradesmen
2 @ $110
48 @ $55
Total = $2860.00 (inc GST)
This is the window lock they recommend, which comes in both white and black.
Once fitted, why is the maintenance of window locks important for continued compliance with child safety window locks legislation in NSW
Anthony Shakar, ASQB points out why Annual Compliance Checks are important:
Once a fall prevention device is attached to a window, it becomes a fixture and part of common property. As a result, the owners’ corporation is responsible for maintaining all fall prevention devices to a standard required by legislation.
Over time, child window safety devices can fail to work effectively causing a window to become non-compliant. The most efficient and effective way to ensure all devices remain in good working order is to carry out an annual compliance check. This will enable any faulty devices to be regularly identified, and rectified, whilst also maintaining a detailed record for the building, thereby minimising any risk.
Maintaining a safe environment for young children is paramount, so it is important that devices are regularly tested and maintained to ensure their effectiveness. Doing so will prevent any serious injuries from occurring, and will ultimately save lives.
How Can a Window Become Non-compliant?
It can be hard to monitor the way in which fall prevention devices are being used by the occupants of individual dwellings, therefore highlighting the importance of carrying out a regular audit. The following are some of the most common ways a window may become non-compliant:
- Misuse of a device, leaving it unable to operate as intended
- Removal of a device, leaving the window unrestricted
- Damage to device, leaving it unable to operate effectively
- Missing keys, leaving the child window safety devices non-compliant
What Does a Window Compliance Check Involve
- The assessment of each window safety device throughout the property, as well as the general condition of each affected window. Each window safety device will be checked in accordance with the Strata Schemes Management Regulations – Child Window Safety.
- Updated Certification issued for each unit. This will include detailed photos for reference.
- If required, on the spot maintenance/ replacement of non-compliant window safety device (time permitting)
Have a question or something to add to the article? Leave a comment below.
Read next:
This article is not intended to be personal advice and you should not rely on it as a substitute for any form of advice.
Visit Maintenance and Common Property OR NSW Strata Legislation pages.
Looking for strata information concerning your state? For state-specific strata information, take a look here.
Are you not sure about some of the strata terms used in this article? Take a look at our NSW Strata Glossary to help with your understanding.
After a free PDF of this article? Log into your existing LookUpStrata Account to download the printable file. Not a member? Simple – join for free on our Registration page.
tim doherty says
the legislation states: the screen is capable of resisting an outward horizontal action of 250 newtons,, this is not rocket science 250 newton is the same as 25 kilogram. to test is apply 25 kilograms of outward force onto the screen. hold a set of bath room scales against the screen and push till it reads 25kg.
‘testing and charging and so called compliance certificate is a rort’
an after thought says
I should add that the window locks used on common property like stairwells most probably breach the ventilation regulations in the i. National Standards 1668.4, and
ii. Building Codes of Australian F4.5 a-1
in other words screens are the only option for common property, locks should never have been used because of ventilation issues
nfw says
Everybody wants to make money out this don’t they? I love the comment about how Lot owners can’t do it as you can’t contract out of a legislative requirement. Well this below is taken straight from the Fair Trading website:
The owners corporation can pass a common property rights by-law which makes the individual lot owners responsible for installing window safety devices.
The owners corporation can also consider adopting the model by-laws (Schedule 3 of the Strata Schemes Management Regulation 2015) which allow individual lot owners to install and repair window safety devices in their own lot without consent.
Bruce says
windows opening 125mm high rise unit will that apply to QLD strata schemes.
Nikki Jovicic says
Hi Bruce
We have received the following response back from Peter Berney, Solutions In Engineering:
There hasn’t been any further talk of Window Child Safety Compliance being made retrospective in Qld. In 2013 the Building Code of Australia changed requiring all buildings with residential lots where the floor is 2 metres or more from ground level and the interior floor to window sill is less than 1.7 metres for all openable windows to be restricted to not open more than 125mm. Only the state of NSW made this retrospective and only under the Strata Management Act. This means that schemes not registered under this Act such as Community Associations, Neighbourhood Schemes and Company title buildings all avoided having to comply.
What can you do if you would like to have the peace of mind of having windows restricted when young children are around?
Well, you can certainly have Window Child Safety Devices installed. A lockable ‘keyed’ device allows the occupier to open the window when children are not present and relock when they are. This is ideal for grandparents for example for when the grandkids come over but don’t live there full time. The Building Codes Qld site states that the most common reasons children fall from windows are:
· Furniture placed below openable windows
· Failure of flyscreens to protect openings
· Non-safety grade glass (often in older buildings where this requirement did not apply at the time of construction)
Building design can play an important part in helping prevent injuries from falls from windows. QISU recommends that where rooms may be used by children, larger openable windows should be avoided and higher positioned louvre-type windows should be used instead.
Despite the technical provisions of the NCC, QISU suggests it would be good practice that where it is likely a child can gain access to a window, the opening should be limited to a maximum of 100 millimetres. To do this, windows can be fitted with devices (to allow a window to only open 100 millimetres for example) or barriers (metal mesh or bars with no opening greater than 100 millimetres). Natural ventilation of rooms will also need to be considered where windows are fitted with these devices or barriers.
Fly screens may be effective barriers for insects, but they do not prevent children from falling out of windows. A metal mesh or grill is a suitable alternative that will allow a breeze through the building.
Di says
I own a 2 story townhouse and have an air-conditioner sealed into the window. The glass has been cut away to install the air conditioner then sealed. It is not possible to open the window.
Other owners who had air conditioners in their windows had unsealed air conditioners ie the window remained open and glass sat on top of air conditioner. These air conditioners had to be removed.
As my air conditioner is sealed into the window do I need to have this removed? If so who should pay as a new window would have to be installed after the air conditioner was removed.
Paul Foot says
who determines the requirements to be a “qualified” inspector of the window locks ?
Elton Lands says
What kinds of windows need a “compliance certificate”?
The Fair Trading NSW website indicates that windows where the height difference between the internal and external floors is less than 2 metres are not required to have safety devices fitted. An example is a window that opens to a balcony (as distinct from a balcony door).
Do we need to have these “not required” windows inspected and have a compliance certificate issued for them as well? (to certify the fact that they are not required by law to have safety devices fitted)
Anne Mayoh says
My unit is on the top floor of a three level 1960 unit block. I have one window, double sash aluminium, which can be opened on to a balcony. The window is approximately 1 metre . from the balcony floor level. Am I correct in assuming this window will not need to be fitted with a lock.
(Update from Admin) Anne got back to us to report: As I had anticipated there was no need for one to be fitted to the window that opened on to the balcony, for which I am extremely grateful as making space for the guy to do the job would have been a real nightmare!
Laura says
Hi guys my building has been quoted by one company to put in the devices but the way they have quoted makes me concerneed as they advise after installing each device, a test must be done on every window incurring an extra seperate fee of $33 per window which is charged once the test is passed. We have over 100 Windows to get done!
Do you know if it a common that suppliers charge additional fees for the test and certificate which documents a window has passed the legislation requirements? Other quotes don’t mention this but could be a hidden charge and I’m not sure of what others have experienced with their buildings.
Nikki Jovicic says
Hi Laura
A test is required, however I’m not sure of the charges. I’ll do some checking and get back to you.
Thanks
Nikki
Anne Moran says
I, like many other owners, don’t have children and I am angry that I am being forced to have these window locks installed. We are being treated as if we are in government subsidised rental accommodation and not home owners. Also, in relation to the cost of the locks, is it true that the owners have to cover the expense?
Regards
Anne Moran
Nikki Jovicic says
Hi Anne
Installing the window locks and complying with this legislation is an Owners Corporation expense.
Gianni Nessuno says
And where do you think the Owners Corporation funds come from ?
Shaun says
Is there a list of locks that comply so that I can choose the right one to install?
Phil Jones says
G’day – As an owner, I am extremely pi$$ed off by this legislation and ask ‘why is it so’ – and I don’t want a bland answer of ‘children don’t fly’. Whatever happened to parental responsibility and acceptance of that responsibility?. Why is it that umpteen million windows across NSW have to be locked down when a substantial percentage of those householders have no children present or rarely present?
My block of units is not large, but 2/3rds of us are “retired oldies” who a) do not have children living on-site, and b) rarely have children visit and then only for a very short visit. Why the hell do we need to lock up our windows for no worthwhile purpose?
Neighbours in other units tell us that not one single tenant or owner is happy with this window lock requirement; others advise us “just remove the locks like we have done”. I have personally looked at window locks as installed in 3 local apartment units … all “professionally” installed
Some have been pop-rivetted in, so can never, ever be opened beyond the 12.5cm limit Others have been screwed in with openings between 100mm and 130mm. ALL vertical opening aluminium framed case windows I have examined fail to open beyond 125mm under any circumstances
And then we come to the issue of fire and emergency egress. When all these windows are locked down and a fire starts, how can children &/or elders escape when the damn window will not open fully?
It also begs the question – how many people are fire rescued annually vs how many children fall out of windows?
I am also receiving comment from local real estate people advising that landlords offering holiday rental units are withdrawing them from the marketplace, as it’s well known that during the hot weather periods, every visitor wants windows opend fully to receive the breeze. Or – the landlord now is advised to install an air-conditioning unit for cooling.
Why should a landlord be forced to install a $4000 air conditioner and suffer the running costs due to locked windows?
Has anyone ever thought about these things – and braved public consultation – “real” public consultation before things are signed off?
Phil Jones says
I posted this comment 2 weeks ago, and no-one has responded. This tells me that the topic of “mandatory” installation of window locks cannot be justified by this organisation – and by extension, unjustifiable by other organisations as well
In my O.P. I posed the idea “It also begs the question – how many people are fire rescued annually vs how many children fall out of windows?”
The 2016 annual report from Fire and Rescue NSW states that they conducted 22,042 fire rescues and 11,520 non-fire rescues during the previous year.
It makes the figures of “50 children Australia wide who are hospitalised annually due to falling from a window” shallow by comparison.
All in all, it’s an appalling system and I for one, will not be installing these window locks into my apartment
Nikki Jovicic says
Hi Phil
Thank you for your comments. LookUpStrata plays no part in forming the legislation. We simply keep lot owners informed about changes that are and will be affecting their strata living. We do our very best to present this information in an unbiased manner.
Thanks
Richard Brincat says
Hi Can I confirm if I have keyed windows locks that securely lock the window in its closed position, Will it meet the legislative requirement?
I have no children so I dont expect to have a restrictor when I have it opened.
Can you please advise if this will meet the requirement
Nikki Jovicic says
Hi Richard,
Thanks for your question. I refer you to the comments made in the article above by both Whitbread Insurance Brokers and Peter Berney, Solutions In Engineering. In particular:
Peter Berney: “The issue is not so much the devise as is the logistics of organising and gaining access and then proof that the devise was fitted and tested to 250 newtons.“
T Kot says
As I’m reading this legislation, the window locks must be fitted, but not necessarily engaged or in use continuously? The reason for the question, in our building, as more investors have bought in, and more ethnics are renting, the winter months are a strong deterrent for opening the windows inside the unit and airing the space. The cooking smell comes into the common area, the windows onto the common area need to be opened to air the common space. The 12.5cms opening is insufficient for airing the common space, as we have learnt from experience in the past 15 years. Aside from changing/replacing the window, what are the legislated rules if a window with slated panes/panels, is installed?
Nikki Jovicic says
Hi T Kot
Thank you for your question. We have received the following reply back from Peter Berney, Solutions In Engineering:
To be compliant, section 30 of the Strata Schemes Management Regulation 2016 (NSW) requires that window safety devices must:
· Be capable of restricting the opening of a window so that a sphere (125mm in diameter) cannot pass through,
· Be capable of resisting an outward force of 250 newtons, and
· Have a child resistant release mechanism
Windows with slated panels would still need to comply with this requirement. This is because a ‘window’ as defined by the Building Code, in relation to s 30 of the Strata Schemes Management Regulation 2016 (NSW), includes: glass panels, glass louvre, or other device which transmits natural light directly from outside a building.
Therefore, your windows will still need to be fitted with an appropriate window safety device – in compliance with the legislation.
John OGrady says
Can someone who is independent tell me if the window locks on our building comply.They are 1.85m from the floor and will resist the force. Fair Trading NO help.
Nikki Jovicic says
Hi John
Thank you for your question. We have received the following reply back from Jeff Schultz, the Business Development Manager at Express Glass:
The legislation specifies that opening windows only need a device capable of restricting the window when engaged if the lowest level of the window is within 1.7m from the internal floor.
You state your windows are 1.85m from the internal floor. If this is the case they would most likely be exempt from the legislation. If you would like piece of mind, Express Glass are able to check and certify buildings but this does incur a fee. They can be contacted at [email protected].
Please let us know if you have further questions, John.
John O'Grady says
I stated that the WINDOW LOCKS are 1.85m from the floor,not the windows.
Does this mean that the window LOCKS comply with the legislation.The locks are such that the window can be locked completely and can resist the required force necessary to open same
Nikki Jovicic says
Thanks John,
We have received this further reply back from Jeff Schultz, Express Glass:
My recommendation is to engage an appropriately qualified tradesman to assess the building and certify his windows comply to ensure the strata is covered in the case of a future accident.
Jane Park says
Hi!
I am getting conflicting information about what is required and would love an answer (if possible) today as I am going to a Strata AGM tonight. I am an owner of a unit in a 1960’s block.
A friend who is in a 1960’s unit block in Dee Why had new windows and locks installed by her supplier. Her supplier said this:
To comply with the Australian Building Code of Australia, Strata Schemes Management Regulation 2016 and the National Construction Code, any opening window that is below the 865mm will need to be permanently restricted to only open by 125mm.
You are saying differently? It sounds like you are saying that we get locks put on, but can have the windows wide open – it kind of defeats the purpose of the “permanently restricted aspect” of the legislation.
Confused!
Jane
ray laws says
Hi Peter
Thanks for the prompt reply – and the good news
ray laws says
Hi Nikki
I’ve just downloaded a ‘Restricted Openings Flow Chart’ from the AWA website. There’s a ‘Child Resistant Restriction’ compliance which you’ve featured on this page (ie: lockable) but the flow chart features another level of compliance: ‘Permanent Restriction’ for all windows within 865mm of the floor. Does this mean the lockable device you feature doesn’t comply?
Nikki Jovicic says
Hi Ray
Thank you for your question. We have received the following reply back from Peter Berney, Solutions In Engineering:
The flowchart is based on the NCC, which is not retrospective. This means that window locks don’t have to be permanently restrictive unless they are in a new building or the property undergoes major work to its windows – your windows only need to comply with the code that existed at the time that your building was constructed. As such, the locks that we supply can be used on your building and do restrict the windows appropriately.
Cheers Peter
John O'Grady says
Given the huge cost of installing window locks thru’ strata buildings in NSW,especially in strata units where NO children are present or unlikely ever to be present,surprised that no pressure has been put on the Gov. to reverse this un-necessary law
How about we introduce legislation to make parents look after their kids,eg we dont have parents ignoring 3&5 year olds bouncing up and down on a bed next to an open window 3 stories up!!!